15kVA~1000kVA Silent/Soundproof Diesel Generator with Cummins Engine
genset Model |
EMW-8 |
EMW-12 |
EMW-15 |
EMW-20 |
EMW-24 |
EMW-30 |
EMW-40 |
EMW-50 |
EMW-64 |
EMW-75 |
EMW-100 |
EMW-120 |
Rated Power (KW) |
8 |
12 |
15 |
20 |
24 |
30 |
40 |
50 |
64 |
75 |
100 |
120 |
Rated Power (KVA) |
10 |
15 |
18.8 |
25 |
30 |
37.5 |
50 |
62.5 |
80 |
94 |
125 |
150 |
Rated Voltage (V) |
220/380,230/400;etc |
220/380 |
Frequency(HZ) |
50 |
50 |
Engine Model |
380D |
480D |
495D |
K4100D |
K4100D |
N4102D |
N4102ZD |
R4105ZD |
R6105ZD |
R6105ZLD |
R6105AZLD |
R6150BZLD |
Rated output (kw) |
11 |
14 |
26.5 |
30.1 |
30.1 |
36 |
48 |
56 |
84 |
100 |
120 |
132 |
Governing method |
Nature |
Nature |
Oil volume (L) |
9 |
9 |
9 |
9 |
11 |
11 |
16 |
16 |
16 |
16 |
24.3 |
24.3 |
Fuel Consumption (g/kw.h) |
251 |
246 |
246 |
246 |
246 |
235 |
230 |
227 |
227 |
218 |
218 |
218 |
Fuel Consumption(L/H) |
3.2 |
4.0 |
7.6 |
8.6 |
8.6 |
9.8 |
12.8 |
14.8 |
22.2 |
25.3 |
30.4 |
33.5 |
Oil Consumption (L/H) |
1.06 |
1.08 |
1.05 |
1.07 |
1.08 |
1.08 |
1.07 |
1.07 |
1.07 |
1.07 |
1.06 |
1.06 |
Exhaust Flow(L/S) |
67.5 |
67.5 |
101 |
101 |
130 |
130 |
250 |
250 |
272 |
276 |
519 |
519 |
Exhaust Temperature |
383 |
380 |
452 |
460 |
463 |
463 |
526 |
526 |
548 |
481 |
536 |
536 |
Water volume (L) |
20 |
20 |
20 |
20 |
25 |
25 |
25 |
25 |
25 |
25 |
28 |
28 |
Cooling System |
Closed water cooled |
Closed water cooled |
Starting Method |
D.C.12V or 24V Electric starting |
D.C.12V or 24V Electric starting |
Alternator model |
Brushless type |
EM-164B |
EM-164D |
EM-184E |
EM-184F |
EM-184G |
EM-184H |
EM-224D |
EM-224E |
EM-224G |
EM-274C |
EM-274D |
EM-274F |
Brush type |
STC-8 |
STC-12 |
STC-15 |
STC-20 |
STC-24 |
STC-30 |
STC-40 |
STC-50 |
/ |
/ |
/ |
/ |
Rated power |
8 |
12 |
15 |
20 |
24 |
30 |
40 |
50 |
64 |
75 |
100 |
120 |
Rated voltage |
220/380,230/400;etc |
220/380 |
Rated current |
15.2 |
22.8 |
28.5 |
38.0 |
45.6 |
57.0 |
76.0 |
95.0 |
121.6 |
142.4 |
189.9 |
227.9 |
Rated frequency |
50HZ |
50HZ |
Rated speed(rpm) |
1500 |
1500 |
Power factor |
0.8 lagging for 3-phase |
0.8 lagging for 3-phase |
Phase connection |
3-phase |
3-phase |
Winding connection |
4-wire connected(12-wire for 3-phase) |
4-wire connected(12-wire for 3-phase) |
Excitation method |
Harmonic or Brushless Excitation |
Harmonic or Brushless Excitation |
Insulation class |
H |
H |
Voltage regulation |
Manual/Automatic |
Manual/Automatic |
CONTROL PANEL |
V-meter,A-meter,Frequency meter,circuit breaker,transfer switch,temp.and pressure gauges,indicating lamp,hour meter,key starter,etc. |
NET WET(kg/Open type) |
560 |
560 |
580 |
630 |
730 |
780 |
840 |
1070 |
1200 |
1250 |
1350 |
1480 |
PACKING SIZE(mm/open type) |
160*70*110 |
165*70*110 |
170*70*110 |
175*76*113 |
190*80*117 |
195*86*133 |
240*93*140 |
248*93*140 |
255*93*145 |
1) Output range: 8KW -40kW/10VA-50KVA
2) Engine model: 380D, 480D, 495D, K4100D, N4102D, N4102ZD
3) Alternator: Stamford type
4) Water-cooled
5) 8hrs operation base tank
6) Key start / auto start
7) Sound-proof / weather-proof canopy is optional
8) 230 / 400V AC, 50Hz / 60Hz, 0.8pF three-phase and four wires alternating current output
9) Frequency: <3%
10) Frequency at stable state: <0.5%
11) Frequency deviation at instantaneous state: ≤ +10%
12) Frequency return time: ≤ 3s
13) Voltage deviation at stable state: ≤ + -1%
14) Voltage deviation at instantaneous state: ≤ +20%
15) Voltage return time: ≤ 4s
16) Voltage modulation: ≤ 0.3%
17) Standard configuration of gensets:
A) Engine: QUANCHAI diesel engine
B) Engine type: Water-cooled, in line four-stoke, dry cylinder liner, direct injection
C) Alternator: Brushless and "H" class insulation
18) Control system:
A) Automatic alarm system: The unit has the acousto-optics alarm system and
Arrestor for any situation as the start defeat, the water is over temperature,
The oil pulls down, over speed, over load and over current
B) Operation display:
I) Unit voltage, tri-phase load current and frequency display
II) Water temperature, oil pressure display
III) Fuel level, fuel temperature display
IV) Audible and visual alarm lamps and buzzers
19) Starting system: DC alternator is used to start engine
20) Short circuit protection: MCCB air switch
21) Cooling system: Combined cooling water tank fitted to meet the requirement of radiation at ambient temperature 40 degree
22) Filter system: Oil, fuel and air filter
23) Accessories: Exhaust elbow, bellow, muffler
24) Supply standard collocation:
A) Diesel engine with all accessories, 3 filter, electric systems
B) Alternator
C) Steel structure
D) Fan and water tank cooling system
E) Flange connector
F) 12 / 24V starting motor and charge engine
G) Air cleaner, fuel cleaner, oil cleaner
H) On-board control panel